GossenGossenGossenGossen
    0
  •   was successfully added to your cart.
  • SPECTRAL PHOTOMETRY
    • MAVOSPEC BASE
    • MAVOSPEC LITE
    • DOWNLOADS
      • PREVIOUS DEVICES
  • LIGHT MEASURING
    • MAVOMASTER – MAVOPROBE
    • MAVOPAD
    • MAVOLUX
      • MAVOBASE LUX
      • MAVOLUX COMPACT
    • MAVO SPOT 2 USB
    • DOWNLOADS
      • PREVIOUS DEVICES
  • PHOTOGRAPHY
    • DIGIPRO F2
    • SIXTOMAT F2
    • DIGIFLASH 2
    • DIGISIX 2
    • DOWNLOADS
      • PREVIOUS DEVICES
  • LIGHT LAB
  • COMPANY
    • ABOUT US
      • COMPANY PROFILE
      • HISTORY
      • IMPRINT
    • JOBS & CAREER
    • CERTIFICATES
    • REPAIR SERVICE
    • PRODUCT RETURNS
    • TRADE FAIRS AND EXHIBITIONS
    • FINDING US
    • TERMS OF DELIVERY AND GUARANTEE
    • CUSTOMER SATISFACTION AND COMPLAINTS
  • CONTACT
    • LIGHT MEASURING DEALERS
      • GERMANY
      • WORLDWIDE
    • PHOTOGRAPHY DEALERS
      • GERMANY
      • WORLDWIDE
  • BLOG
  • SHOP
    • MY ACCOUNT

MAVOBASE LUX

LED_comatible

MAVOBASE LUX

The precise illuminance meter

Due to its Class C accuracy, it is primarily used as an operational measuring instrument in the planning and installation of lighting systems, as well as for their inspection and monitoring, and to ensure compliance with prescribed lighting conditions.

The device covers a wide measurement range from 0.1 lx to 199,900 lx with an accuracy of ±3% ±1 digit. The deviation of the V(λ) adjustment, f1’ < 7.5%, is significantly better than the permissible error limit specified by Class C standards.

During operation, the device allows users to retrieve and display the minimum and maximum measured values as well as the calculated average value at any time. Additionally, the REL measurement functionality enables the measurement of artificial light under daylight or diffuse light conditions.

At GOSSEN, safety through calibration is a top priority. As proof, a factory or DAkkS (ISO 17025) calibration certificate can be issued upon request. Depending on the device’s operating conditions, a calibration interval of 12 to 24 months is recommended.

 

BUY NOW
TECHNICAL DATA
Buy Now

TECHNICAL DATA

MAVOBASE LUX
Specifications

HIGHEST PRECISION

Classified measurement of illuminance in lx or fc according to Class C as specified in DIN 5032-7, DIN EN 13032-1 Annexes B and C, and CIE 69.

COSINE CORRECTION

When measuring illuminance, the angle of incidence of the light is taken into account. 

WIDE MEASUREMENT RANGE

High initial sensitivity and resolution of 0.1 lx and 0.01 fc, respectively, up to high illuminance levels of 199,900 lx and 1,9990 fc, respectively.

CALIBRATION

Optionally, the accredited GOSSEN lighting laboratory can issue a factory or DAkkS calibration certificate for the monitoring of measuring equipment in accordance with DIN EN ISO 9001:2015.

V(λ) ADAPTION

The spectral sensitivity of the silicon photodiode is color-corrected and matches the spectral luminance sensitivity of the human eye, V(λ).

PRECISE MEASUREMENTS

The accuracy is ±3% ±1 digit of the reading.

MEASUREMENT FUNCTIONALITIES

PEAK & REL functions for determining MIN/MAX/AVG values, as well as for measurements under daylight and diffuse light conditions.

COMFORTABLE FOR EVERYDAY USE

Easy to use, with a clear display and a compact design. A high-quality plastic case with a custom-fit foam insert is available as an option for transport.

  • MEDICAL TECHNOLOGY

    light measuring

    MEDICAL TECHNOLOGY

    light measuring

  • STAGE, STUDIO AND FILM LIGHTING

    light measuring

    STAGE, STUDIO AND FILM LIGHTING

    light measuring

  • DISPLAYS, MONITORS, LARGE-FORMAT DISPLAYS & PROJECTORS

    light measuring

    DISPLAYS, MONITORS, LARGE-FORMAT DISPLAYS & PROJECTORS

    light measuring

Downloads

MANUALS

MAVOBASE LUX
Download_Icon MANUAL (PDF)
German
Download_Icon MANUAL (PDF)
English
Download_Icon MANUAL (PDF)
French
Download_Icon MINMAL VALUES ASR A3.4 (PDF)
Table minimal values ASR A3.4
Download_Icon EU CONFORMITY DECLARATION (PDF)
CE-Declaration MAVOBASE LUX

CATALOGUES

MAVOBASE LUX
Download_Icon FLYER (PDF)
MAVOBASE LUX German
Download_Icon FLYER (PDF)
MAVOBASE LUX English
Download_Icon PHOTOMETRY COMPENDIUM (PDF)
German
Download_Icon PHOTOMETRY COMPENDIUM (PDF)
English

PRESS INFORMATION

MAVOBASE LUX
Download_Icon PRESS INFORMATION (PDF)
German
Download_Icon PRESS INFORMATION (PDF)
English
Download_Icon PRESS PICTURES
300 dpi
PREVIOUS MODELS

MAVOBASE LUX – Technical Data

Class C DIN 5032-7 / EN 13032-1 Anhang B

MEASURING FUNCTIONS

MAVOBASE LUX
Illuminance [Lux] 0,1 lx … 199 900 lx / 0,01 fc … 19990 fc
Measurement Ranges 4
Range Switch Auto
Sampling Rate  2/s
Measurement Method Distance Measurement
Measuring Sensor Silicon photodiode with V(λ) filter
Sensor with Tripod Thread Yes
Measurement cable  1,5 m, permanent connection
Product standard DIN 5032-7 class C / DIN EN 13032-1 appendix B / ISO CIE 19476
V(λ) matching (f1‘) typical < 7,5 %
Cos φ (f2‘) rating typical
≤ 2 %
Accuracy  ± 3 % v. Ablesung ± 1 Digit

POWER SUPPLY

MAVOBASE LUX
Battery 1 x 1,5V Mignon , Type AA
Automated battery control Yes
Automated switch-off 4 min / Continuous
Battery life approx. 45 h Alkali-Mangan-Batteriy
Continuous mode USB connection

OPTIONAL ACCESSORIES

MAVOBASE LUX
WERKSZERTIFIKAT
H997B
DAkkS ZERTIFIKAT
H997D
KUNSTSTOFFTRANSPORTKOFFER
M520G

OPERATION

MAVOBASE LUX
Display 3 1/2 digit
Control elements 6 Buttons
Display back-lit graphical ddisplay
Software Not implemented

MISCELLANEOUS

MAVOBASE LUX
Operating temperature 0 °C to 50 °C
Dimensions 65 mm x 120 mm x 19 mm (Display unit)
31 mm x 105 mm x 30 mm (Sensor head)
Weight 200 g excl. Battery
Scope of delivery Battery, manual, end test certificate
Subject to technical changes 

 

GOSSEN Foto- und Lichtmesstechnik GmbH . Lina-Ammon-Str. 22 . 90471 Nürnberg
T +49 911 800621 0 . F +49 911 800621 29 . info@gossen-photo.de

© 2026 GOSSEN Foto- und Lichtmesstechnik GmbH
Imprint | Terms of Delivery and Guarantee | Data Policy
  • German
  • English
  • SPECTRAL PHOTOMETRY
    • MAVOSPEC BASE
    • MAVOSPEC LITE
    • DOWNLOADS
      • PREVIOUS DEVICES
  • LIGHT MEASURING
    • MAVOMASTER – MAVOPROBE
    • MAVOPAD
    • MAVOLUX
      • MAVOBASE LUX
      • MAVOLUX COMPACT
    • MAVO SPOT 2 USB
    • DOWNLOADS
      • PREVIOUS DEVICES
  • PHOTOGRAPHY
    • DIGIPRO F2
    • SIXTOMAT F2
    • DIGIFLASH 2
    • DIGISIX 2
    • DOWNLOADS
      • PREVIOUS DEVICES
  • LIGHT LAB
  • COMPANY
    • ABOUT US
      • COMPANY PROFILE
      • HISTORY
      • IMPRINT
    • JOBS & CAREER
    • CERTIFICATES
    • REPAIR SERVICE
    • PRODUCT RETURNS
    • TRADE FAIRS AND EXHIBITIONS
    • FINDING US
    • TERMS OF DELIVERY AND GUARANTEE
    • CUSTOMER SATISFACTION AND COMPLAINTS
  • CONTACT
    • LIGHT MEASURING DEALERS
      • GERMANY
      • WORLDWIDE
    • PHOTOGRAPHY DEALERS
      • GERMANY
      • WORLDWIDE
  • BLOG
  • SHOP
    • MY ACCOUNT
  • German
  • English
Gossen
    0 items