{"id":20078,"date":"2023-04-17T15:29:50","date_gmt":"2023-04-17T13:29:50","guid":{"rendered":"https:\/\/gossen-photo.de\/?p=20078"},"modified":"2023-04-17T15:29:50","modified_gmt":"2023-04-17T13:29:50","slug":"komfortable-beurteilung-der-beleuchtung-von-arbeitsstaetten","status":"publish","type":"post","link":"https:\/\/www.gossen-photo.de\/en\/komfortable-beurteilung-der-beleuchtung-von-arbeitsstaetten\/","title":{"rendered":"CONVENIENT ASSESSMENT OF LIGHTING IN WORKPLACES"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<div class=\"page\" title=\"Page 1\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p>When planning the lighting of workplaces, the standards DIN EN 12464-1 for indoor workplaces, DIN EN 12464-2 for outdoor workplaces and DIN EN 1838 for emergency lighting as well as the technical rules for workplaces ASR 3.4 lighting and ASR 3.4\/3 safety lighting come into use. You can find more information on this in our blog post<\/p>\n<p><strong><a class=\"tiptip\" href=\"https:\/\/www.gossen-photo.de\/en\/workplace-lighting-standards-and-regulations\/\">WORKPLACE LIGHTING \u2013 STANDARDS AND REGULATIONS<\/a><\/strong><\/p>\n<p>They contain specifications about the average and minimum illuminance to be maintained, as well as the resulting uniformity of the lighting. GOSSEN has developed a special <strong>grid measurement function (GRID)<\/strong> for this purpose and implemented it in the MAVOMASTER, the universal basic device of the new light measurement system. When the measuring function is activated, the current measured value of the grid point is accepted at the push of a button, Emin \/ Emax \/ Eavg \/ U0 \/ UD of the measurement series is automatically calculated and made available for retrieval. This means that the workplace lighting can already be assessed during the measurement. When the measurement function is ended, all measured values and the values calculated from them can be saved in CSV format and are available for creating an acceptance report.<\/p>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-20103 size-full\" src=\"https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB.jpg\" alt=\"\" width=\"2431\" height=\"1157\" srcset=\"https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB.jpg 2431w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-300x143.jpg 300w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-1024x487.jpg 1024w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-768x366.jpg 768w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-1536x731.jpg 1536w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-2048x975.jpg 2048w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-800x380.jpg 800w, https:\/\/www.gossen-photo.de\/wp-content\/uploads\/2023\/04\/GRID_Bedienung_GB-535x255.jpg 535w\" sizes=\"auto, (max-width: 2431px) 100vw, 2431px\" \/><\/p>\n<p style=\"text-align: center;\"><em>MAVOMASTER Screenshots &#8211; grid measurement function (GRID)<\/em><\/p>\n<p>The MAVOLUX 5032 B kit contains the MAVOMASTER and the MAVOPROBE 5032 B with very high resolution and accuracy. This means that the user is ideally equipped to check the illuminance in accordance with the standards and rules listed above.<\/p>\n<p><strong><a href=\"https:\/\/www.gossen-photo.de\/en\/mavomaster\/\">MAVOMASTER, MAVOPROBE<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_row_inner][vc_column_inner][vc_empty_space]<style type=\"text\/css\" >#l_rnkzkwqd6fafj437scbg.sc_line ,#l_rnkzkwqd6fafj437scbg .sc_line { height:1px; background:#a9a793;}#l_rnkzkwqd6fafj437scbg {margin:0px 0 0px 0; padding:0;}<\/style><div class=\"clearfix\"><\/div><div id=\"l_rnkzkwqd6fafj437scbg\"  class=\"sc_line rd_line_normal\" ><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>GOSSEN has implemented a special grid measurement function (GRID) in its new luxmeter series MAVOMASTER, MAVOPROBE for comfortable assessing workplace lighting.<\/p>\n","protected":false},"author":5,"featured_media":20083,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[273],"tags":[],"class_list":["post-20078","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-light-measuring"],"_links":{"self":[{"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/posts\/20078","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/comments?post=20078"}],"version-history":[{"count":6,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/posts\/20078\/revisions"}],"predecessor-version":[{"id":20105,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/posts\/20078\/revisions\/20105"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/media\/20083"}],"wp:attachment":[{"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/media?parent=20078"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/categories?post=20078"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.gossen-photo.de\/en\/wp-json\/wp\/v2\/tags?post=20078"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}